Twenty, lamps
1. Look and feel requirements:
The exposed surface is clean, free of scratches and spots, and free of any other damage.
2. Technical measures:
a) The lamps and lanterns should have complete and intact packaging when they enter the site, and the packaging should be opened in front of the construction. The construction unit, project management personnel and supervision company must make corresponding records according to the household and the piece;
b) The installer should wear clean white cotton gloves and clean the tools before installing the lamp;
c) After the lamp installation is completed, the necessary dustproof and protective treatment should be carried out.
21. Panels such as switches and sockets
1. Look and feel requirements:
a) The exposed surface is clean, without scratches and spots, and without any other damage;
b) The color of the panel materials of the same brand should be consistent;
c) The junction between the panel and the wall is clean.
2. Technical measures:
a) When the panel enters the site, there should be intact packaging. The packaging can be opened in front of the construction. The construction unit, project management personnel and supervision company must make corresponding records according to households and pieces;
b) The installer should wear clean white cotton gloves and clean the tools before installing the panel;
c) After the panel base is installed, the surface should be sealed with textured paper and other materials to prevent pollution.
22. Door locks and hardware
1. Look and feel requirements:
There should be no visible defects such as breakage, scratches, or burrs.
2. Technical measures:
The materials should be packed with soft materials when entering the field. After installation, the foam film should be used for overall packaging protection and tape fixing, but the tape material is not allowed to directly contact the door lock and the door body.
Twenty-three, flat roof aluminum plate, tuyere hundred pages
1. Look and feel requirements:
The surface should be flat, clean and consistent in color, and no scratches, spots, pollution, etc. are allowed.
2. Technical measures:
The materials should be in perfect packaging when entering the field, and the aluminum plate must be protected by veneer.
3. Organizational measures:
a) Installation should be completed basically indoors and before floor paving;
b) Before and after installation, the surface appearance quality should be fully checked, and all materials that do not meet the appearance requirements should be returned.
24. Protection of indoor stairs and elevator cars
1. For the decoration and protection of indoor stairs, three principles should be ensured:
a) If stairs with wooden veneer are used, ensure that the protective layer and the wooden veneer are in soft contact;
b) If stone or other hard materials are used as step finishes, make sure that the step angle is reliably protected;
c) The protective layer should have a reliable fixing method.
2. Pay attention to two points for the protection of finished products of indoor elevators:
a) Protection of call box and elevator door cover;
b) Protection of the elevator door track parts, the four walls inside the car and the top of the car.
25. Requirements for stone transportation
1. When packing stone, try to install the same area and the same set of products in the same box to facilitate dismantling and installation. And paste two splicing installation diagrams and packing slips outside the box to facilitate customers to find and guide on-site installation.
2. When the board is boxed, the marble is facing the light side, separated by a rubber pad in the middle, wrapped with cardboard corners to prevent the corners from collapsing, and the bottom of the wooden box is not less than 2mm thick rubber pad to prevent the stone edge from directly Connect with wood